Sy-bx-200 portable gas analyzer technical scheme

Sy-bx-200 portable gas analyzer technical scheme

 

clip_image001.png


Sy-bx-200 portable gas analyzer is designed based on the principles of infrared, ultraviolet absorption, TDLAS, electrochemistry, PID, etc. Portable use of advanced correlation filtering technology (GFC) at home and abroad. Multiple infrared and electrochemical sensors are built in the instrument. The signal spectrum of cross analysis is used as reference signal, and the signal of gas to be measured is used as reference signal. The signal is subtracted by digital circuit to get the signal change of measured gas. At this time, the change of signal depth is the gas concentration value. The signal is converted into voltage signal, amplified by gain, and passed through microcomputer 10 Segment linearization data, and finally display the gas preparation concentration through the display screen.


Instrument introduction 

1、 Purpose and scope of use

Sy-bx-200 portable gas analyzer adopts high-precision sensor, which is designed for portable measurement. It is easy to carry, fast and stable performance analyzer. It works without consumables, sensitive and easy to operate.

It is suitable for various health and epidemic prevention supervision departments, industry (cement, chemical industry, metallurgy, electric power, etc.), environmental monitoring departments and other scientific research units to detect Co, CO2, SO2, no, O2, HF, HCl, NH3, H2S and other special instruments for gas concentration. 

The instrument has a wide range of detection, from the micro level (PPM) to the constant level (%) can accurately measure its concentration.


Technical parameters:

 

CO

0~50.0、0~100.0、0~500、0~1000PPM、0-2%、0-100%单选。

采样

内置高性能隔膜泵,流量1~1.5L/分

CO2

0~50.0、0~100.0、0~500、0~1000PPM、0-2%、0-100%单选。

线性误差

≤±2%F.S(红外)

SO2

0~100.0、0~500.0、0~2000、0~5000、0~8000PPM

重复性误差

≤±1%F.S

NO

0~100.0、0~500.0、0~2000、0~5000、0~8000PPM

响应时间

微量<60s  常量<15s

HF

0-50,0-200,0-500,0-1000,0-2000PPM

水气干扰误差

≤±1.5%(红外)

O2

0-25%

跨度漂移

≤±2%FS/4H

NH3

0~100.0、0~500.0、0~2000、0~5000、0~8000PPM

使用环境

温度-10℃~+50℃ ,湿度:≤85%RH

H2S

0~100.0、0~200.0、0~1000、0~2000PPM

尺寸

长180*宽90*高245(MM)

HCL

0~100.0、0~200.0、0~1000、0~2000PPM

电源

220VAC,50HZ

CL2

0~100.0、0~200.0、0~1000、0~2000PPM

重量

约5-10KG

显示

液晶显示屏(带背光)、(蓝底白字屏和绿底黑字屏可选)

附件

携带背包、说明书、充电器、内置校零管

分辨率

最低1PPM(0-50PPM)红外

软件内容

实时数据显示,曲线图,柱状图,历史记录曲线图,历史数据等。

 

main features 

1. Infrared, ultraviolet absorption, TDLAS, electrochemistry, PID and other measuring principles are selected for the instrument monitoring. The built-in semiconductor cooling elements or the whole process of high-temperature pretreatment make the temperature in the probe balanced, thus having little impact on the change of outdoor temperature. The probe has long service life, high accuracy and fast response speed.

2. It adopts the advanced technology of gas filter (GFC) in the world, and adopts the design and manufacture of fine absorption spectrum, with strong anti transverse coherence. 

3. High resolution, 0.1-10ppm minimum 

4. The circuit is advanced, and the current popular micro-computer chip and 16 bit high-efficiency AD conversion chip are selected. The whole machine has reasonable design, good circuit stability, small drift, low failure rate and convenient maintenance and repair. The unique automatic gain system can automatically adjust the best working parameters, thus avoiding the index drop caused by the parameter voltage change after the machine aging.

5. Built in high-performance rechargeable battery pack, working for more than 6 hours, and can be external AC power supply, working state can also be charged.

6. Built in high efficiency diaphragm pump, the air flow rate is 1l-1.5l per minute. Directly using this instrument, the external gas can be extracted for analysis.

7. The constant temperature device is selected as the sampling probe, which ensures the normal extraction and protects the probe rod working at high temperature when it is inserted into the cigarette head for sampling in a short time.

8. Built in complete set of pretreatment, filtration, condensation, voltage stabilization and current stabilization to send the stable and pure products to the instrument for analysis

9. Large resolution touch screen, convenient and fast operation, good outdoor backlight.