NOx converter (cabinet type / wall mounted) model sy-nox-a / b
Technical features: the NO2 → no converter is based on the NO2 in the air. In the NO2 → no converter, the furnace temperature is controlled at 280 ℃ ~ 320 ℃, and the NO2 is reduced to no under the effect of the converter (reduction).
Temperature control range: 280 ℃ ~ 320 ℃
Sample gas processing capacity: 300L / h
Pressure range of input sample gas: ≤ 3bar
Control accuracy: ± 1 ℃
Factory set temperature: 298 ℃
Flow range: 0.5-2.0l/min
Conversion efficiency: > 96%